Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J. bras. pneumol ; 33(1): 57-61, jan.-fev. 2007. graf
Artigo em Português | LILACS | ID: lil-452352

RESUMO

OBJETIVO: Verificar a influência da permanência em temperatura ambiente na análise da transportabilidade por ação ciliar e por tosse e do ângulo de contato do muco traqueobrônquico. MÉTODOS: Foi coletado muco hialino de 30 indivíduos sem doença pulmonar, e purulento de vinte pacientes com bronquiectasia. As amostras foram analisadas logo após a coleta e novamente após 24 h. RESULTADOS: Para o muco purulento, após 24 h em temperatura ambiente, houve aumento no deslocamento por tosse (96 ± 50 vs. 118 ± 61 mm) e diminuição do ângulo de contato (32 ± 6 vs. 27 ± 6 graus) (p < 0,05). Para o muco hialino não houve alterações nas medidas analisadas. CONCLUSÃO: O muco traqueobrônquico hialino pode ser armazenado em temperatura ambiente por 24 h sem que haja alterações em sua transportabilidade por ação ciliar ou em seu ângulo de contato. Por outro lado, o muco purulento não deve permanecer em temperatura ambiente por muitas h para que não se altere seu ângulo de contato e sua transportabilidade por tosse.


OBJECTIVE: To evaluate the effect that maintaining tracheobronchial sputum at room temperature has on the analysis of ciliary transport and cough, as well as on the contact angle. METHODS: Hyaline sputum was collected from 30 individuals without pulmonary diseases, and purulent sputum was collected from patients with bronchiectasis. The samples were analyzed immediately after collection and again after 24 h. RESULTS: After 24 h at room temperature, the purulent sputum presented an increase in cough-induced dislodgment (96 ± 50 vs. 118 ± 61 mm) and a decrease in the contact angle (32 ± 6 vs. 27 ± 6 degrees) (p < 0.05). For the hyaline sputum, there were no alterations in the parameters analyzed. CONCLUSION: Hyaline tracheobronchial sputum can be stored in room temperature for 24 h without presenting alterations in ciliary transport or contact angle. However, purulent sputum should not be stored at room temperature for many hours, since ciliary transport and contact angle might be altered as a result.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Tosse/fisiopatologia , Muco/química , Manejo de Espécimes/métodos , Escarro/química , Temperatura , Depuração Mucociliar/fisiologia , Estatísticas não Paramétricas , Fatores de Tempo
2.
Brasília méd ; 44(4): 308-311, 2007. tab
Artigo em Português | LILACS-Express | LILACS | ID: lil-495682

RESUMO

Objetivo. Verificar a confiabilidade de obter a ventilação voluntária máxima por meio de estimativas com base no volume expiratório forçado no primeiro segundo (VEF1) em pacientes com doença pulmonar obstrutiva crônica. Método. Participaram do estudo 32 pacientes com doença pulmonar obstrutiva crônica, sendo 21 homens, com média de idade de 66 ± 8,3 anos. Todos foram submetidos a espirometria e a prova de ventilação voluntária máxima. Foram utilizados os testes de Friedman e de Wilcoxon para comparar a ventilação em estudo, obtida de modo indireto com o valor encontrado por espirometria. O nível de significância preestabelecido foi 5%. Resultados. Dentre as fórmulas indiretas para estimar a ventilação voluntária máxima, apenas a VEF1 x 40 apresentou aproximação com essa ventilação, obtida diretamente (p < 0,05). Conclusão. A melhor estimativa indireta capaz de substituir a medida direta da ventilação voluntária máxima, em pacientes com doença pulmonar obstrutiva crônica, é a fórmula VEF1 x 40.


Objective. To avaluate the reliability of obtaining the maximum voluntary ventilation via estimate values of the forced expiratory volume in the first second (FEV1) in patients with chronic obstructive pulmonary disease. Method. The population was composed of 32 patients with chronic obstructive pulmonary disease, 21 of which were male, and with a mean age in the range of 66 ± 8.3 years. All the patients undergone espirometry and maximum voluntary ventilation test. Friedman’s and Wilcoxon’s tests were used to compare indirect values of maximum voluntary ventilation with those obtained via espirometry. Values were considered statistically significant if p < 0.05. Results. Amongst the indirect formulae used to estimate the maximum voluntary ventilation only FEV1 x 40 showed an approximation with the directly obtained value of MVV (p < 0.05). Conclusion. Formula FEV1 x 40 is the best indirect estimate capable of replacing the direct measure of maximum voluntary ventilation in patients with chronic obstructive pulmonary disease.

3.
J. bras. pneumol ; 32(3): 207-212, maio-jun. 2006. tab, graf
Artigo em Português | LILACS | ID: lil-446343

RESUMO

OBJETIVO: Verificar o padrão da oximetria noturna em portadores de doença pulmonar obstrutiva crônica sem apnéia do sono e com hipoxemia leve em vigília, identificar prováveis parâmetros diurnos capazes de predizer a dessaturação noturna e verificar sua influência no padrão de sono. MÉTODOS: Avaliaram-se 25 pacientes, divididos em dois grupos: com e sem dessaturação noturna. RESULTADOS: Comparando-se o primeiro grupo (52 por cento) com o segundo observou-se: idade, 63 ± 5 versus 63 ± 6 anos; volume expiratório forçado no primeiro segundo, 53 ± 31 por cento versus 56 ± 19 por cento do previsto; relação entre volume expiratório forçado no primeiro segundo e capacidade vital forçada, 49 ± 14 por cento versus 52 ± 10 por cento; pressão parcial de oxigênio no sangue arterial, 68 ± 8mmHg versus 72 ± 68mmHg; saturação arterial de oxigênio, 93 ± 2 por cento versus 94 ± 1 por cento. O grupo com dessaturação noturna apresentou menores valores de saturação arterial de oxigênio diurna e saturação periférica de oxigênio noturna. Não houve diferença no padrão de sono entre os grupos. Houve correlação da relação entre o volume expiratório forçado no primeiro segundo e a capacidade vital forçada, pressão parcial de oxigênio no sangue arterial e saturação arterial de oxigênio diurnas, e saturação periférica de oxigênio no exercício com os níveis de saturação periférica de oxigênio noturna, porém somente a saturação arterial de oxigênio diurna foi preditora da dessaturação noturna. CONCLUSÃO: A única variável capaz de predizer dessaturação noturna foi a saturação arterial de oxigênio diurna. A dessaturação noturna não influencia o padrão de sono de portadores de doença pulmonar obstrutiva crônica com hipoxemia diurna leve.


OBJECTIVE: To determine the nocturnal oximetry pattern in chronic obstructive pulmonary disease patients having no sleep apnea and presenting mild daytime hypoxemia, to identify probable daytime parameters capable of predicting nocturnal desaturation, and to evaluate the influence of nocturnal desaturation on the sleep pattern of these patients. METHODS: Twenty-five patients were divided into two groups: those with nocturnal desaturation and those without. RESULTS: Comparing the first group (52 percent) with the second, we found the following: age, 63 ± 5 years versus 63 ± 6 years; forced expiratory volume in the first second = 53 ± 31 percent versus 56 ± 19 percent predicted; ratio of forced expiratory volume in the first second to forced vital capacity, 49 ± 14 percent versus 52 ± 10 percent; arterial oxygen tension, 68 ± 8 mmHg versus 72 ± 68 mmHg; and arterial oxygen saturation, 93 ± 2 percent versus 94 ± 1 percent. Patients in the nocturnal desaturation group presented lower daytime arterial oxygen saturation and nocturnal arterial oxygen saturation by pulse oximetry. There was no difference between the two groups in terms of the sleep patterns observed. The ratio of forced expiratory volume in the first second to forced vital capacity was found to correlate with forced vital capacity, daytime arterial oxygen tension and daytime arterial oxygen saturation. In addition, arterial oxygen saturation by pulse oximetry during exercise was found to correlate with nocturnal arterial oxygen saturation by pulse oximetry. However, only daytime arterial oxygen saturation was predictive of nocturnal desaturation. CONCLUSION: The only variable capable of predicting nocturnal desaturation was daytime arterial oxygen saturation. Nocturnal desaturation did not influence the sleep patterns of patients with chronic obstructive pulmonary disease accompanied by mild daytime hypoxemia.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Hipóxia , Oxigênio/sangue , Doença Pulmonar Obstrutiva Crônica/sangue , Sono/fisiologia , Gasometria , Índice de Massa Corporal , Estudos Transversais , Hipóxia , Polissonografia , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Índice de Gravidade de Doença , Espirometria
4.
J. bras. pneumol ; 32(2): 123-129, mar.-abr. 2006. tab, graf
Artigo em Português | LILACS | ID: lil-433228

RESUMO

OBJETIVO: Avaliar o efeito do método Reequilíbrio Toracoabdominal na força dos músculos respiratórios de pacientes com fibrose cística, acompanhados no Ambulatório de Fibrose Cística da Universidade Católica de Brasília. MÉTODOS: A amostra, constituída de 29 fibrocísticos, foi caracterizada com base em dados antropométricos, genéticos e de colonização bacteriana. Espirometria, manovacuometria e antropometria foram realizadas antes e depois do tratamento fisioterapêutico, no qual se utilizou o método Reequilíbrio Toracoabdominal, duas vezes por semana, durante quatro meses. RESULTADOS: Houve aumento da pressão inspiratória máxima e da pressão expiratória máxima após o tratamento fisioterapêutico em todos os pacientes, naqueles sem distúrbio ventilatório obstrutivo e naqueles com distúrbio ventilatório obstrutivo leve (p < 0,05). Foi encontrada correlação positiva entre a idade e a pressão expiratória máxima para a maioria dos grupos. A pressão inspiratória máxima só apresentou correlação positiva com a idade no grupo com distúrbio ventilatório obstrutivo leve (p = 0,012; r = 0,817). Para o sexo feminino e para o grupo sem distúrbio ventilatório obstrutivo houve correlação negativa entre a pressão expiratória máxima e a colonização por Pseudomonas aeruginosa (p = 0,036; r = -0,585). CONCLUSÃO: Para os fibrocísticos avaliados, o método Reequilíbrio Toracoabdominal aumentou a força dos músculos respiratórios, o que reafirma a importância do tratamento fisioterapêutico para estes pacientes.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Músculos Abdominais/fisiologia , Exercícios Respiratórios , Fibrose Cística/reabilitação , Força Muscular/fisiologia , Músculos Respiratórios/fisiologia , Índice de Massa Corporal , Fibrose Cística/genética , Fibrose Cística/microbiologia , Volume Expiratório Forçado/fisiologia , Genótipo , Pseudomonas aeruginosa/isolamento & purificação , Índice de Gravidade de Doença , Espirometria , Resultado do Tratamento , Capacidade Vital
5.
J. bras. pneumol ; 31(2): 118-124, mar.-abr. 2005.
Artigo em Inglês, Português | LILACS | ID: lil-404380

RESUMO

INTRODUÇAO: A reabilitação pulmonar é amplamente preconizada para o tratamento da doença pulmonar obstrutiva crônica. OBJETIVO: Avaliar a eficácia da reabilitação pulmonar na capacidade de exercício, força da musculatura respiratória e qualidade de vida de portadores de doença pulmonar obstrutiva crônica. MÉTODO: Em um ensaio clínico não-randomizado e aberto, foram avaliados 27 portadores de doença pulmonar obstrutiva crônica admitidos em programa de reabilitação pulmonar, estáveis clinicamente e ex-tabagistas. Todos os pacientes foram avaliados antes e depois da reabilitação pulmonar. RESULTADOS: A média de idade foi de 65 ± 5 anos, o índice de massa corporal 25 ± 4 kg/m², o volume expiratório forçado no primeiro segundo 55 ± 25 por cento do previsto, a relação entre volume expiratório forçado no primeiro segundo e capacidade vital forçada 50 ± 12 por cento, e a pressão parcial de oxigênio no sangue arterial 70 ± 7mmHg. Comparando os valores antes e depois da reabilitação pulmonar, houve melhora na distância percorrida no teste de caminhada de seis minutos (513 ± 99 m vs 570 ± 104 m), na carga máxima para membros superiores (2 ± 1 Kg vs 3 ± 1 Kg), na pressão inspiratória máxima (-89±23 cmH2O vs -102±23 cmH2O) e nos domínios atividade, impacto e escore total do questionário do Hospital Saint George na doença respiratória. CONCLUSAO: A reabilitação pulmonar, com enfoque no treinamento físico, e realizada de forma criteriosa, é eficaz na promoção do aumento da distância percorrida no teste de caminhada de seis minutos, da carga máxima para membros superiores, da pressão inspiratória máxima e da qualidade de vida.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Exercícios Respiratórios , Pneumopatias Obstrutivas , Qualidade de Vida , Terapia por Exercício/métodos
6.
J. bras. pneumol ; 30(5): 439-444, set.-out. 2004. tab, graf
Artigo em Português | LILACS | ID: lil-392544

RESUMO

INTRODUÇAO: A Reabilitação Pulmonar (RP) melhora a qualidade de vida de pacientes portadores de doença pulmonar obstrutiva crônica (DPOC). No entanto, o papel da RP sobre o padrão de sono destes pacientes ainda não está estabelecido. OBJETIVO: Avaliar a influência da RP sobre o padrão de sono de pacientes portadores de DPOC. MÉTODO: Foram estudados 27 pacientes (22 homens), que foram submetidos a exames espirométricos, gasométricos, antropométricos e polissonográficos antes e depois de seis semanas de RP, além de responderem a escala de sonolência de Epworth. A análise estatística foi realizada pelo teste t de Student para amostras pareadas, ANOVA e o teste de comparações múltiplas Newmans-Keuls. RESULTADOS: Observamos que os pacientes estudados tinham idade média de 63 ± 5 anos, VEF1 = 55 ± 25 por cento do previsto, VEF1/CVF = 50 ± 12 por cento, PaO2 em repouso de 70 ± 7mmHg e SaO2 igual a 94 ± 2 por cento. A polissonografia revelou sono fragmentado, redução do sono delta e dessaturação da hemoglobina, cujas maiores quedas ocorreram durante o sono REM. Não houve diferença estatisticamente significativa (p>0,05) na comparação entre as variáveis estudadas antes e após RP. CONCLUSAO: No grupo de pacientes estudados, o programa de RP não modificou o padrão de sono.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Pneumopatias Obstrutivas , Qualidade de Vida , Transtornos do Sono-Vigília , Análise de Variância , Gasometria , Polissonografia , Espirometria
7.
Fisioter. Bras ; 4(2): 129-132, mar.-abr. 2003.
Artigo em Português | LILACS | ID: lil-361944

RESUMO

O presente trabalho tem objetivo apresentar aspectos basicos do transporte muco por açao ciliar e por tosse. Para isto, sao apresentados,alem dos mecanismos de trasnporte do muco, as formas de coleta do muco, sua composiçao e suas principais propriedade fisicas, com seus respectivos metodos de estudo.


Assuntos
Muco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA